OUR STRENGTHS |
MODULAR SHIELDING Self-standing structure up to 18 (40) GHz Steele stiffeners |
OPTIMISED ABSORBER LINING Microwave pyramidal absorbers (walls and ceiling) Removable pyramidal absorbers for emission & immunity (floor) Truncated type on the ceiling above test volume |
||
DOOR Manual single leaf swing door Clearance 1.2 x 2.1 m |
RAISED FLOOR With ground plane |
||
WALL PANELS Penetration panel including coaxial feedthroughs and waveguides |
TURNTABLE Diameter 1.2 m - Max payload 500 kg |
||
VENTILATION Honeycomb air vents 300 x 300 mm up to 18 (40) GHz |
PROJECT REALISATION Project management Technical design & study On-site installation |
||
POWER DISTRIBUTION Power filter single-phase 32 A Power filter three-phase 32 A Electrical package: power distribution, lighting |
PERFORMANCE VERIFICATION Shielding effectiveness at 900 MHz at critical locations |
AVAILABLE OPTIONS
› Shielded control and amplifier rooms
› Extended shielding performances up to 40 GHz
› Plastic paint for pyramidal absorbers with wide range of colors
› Other types and dimensions of doors
› Electrically-assisted door’s latching/unlatching
› Antenna positioner
› Floor hatches with connection points
› Additional power filters, data filters and special feedthroughs
› CCTV/audio monitoring systems
› On request, some measurements can be accredited ISO 17025 (accreditation number 1-6220).
› Military /Automotive / RadioCom standards compliance
› Others on demand
Номер в Госреестре |
Наименование СИ |
Обозначение типа СИ |
Изготовитель |
Срок свидетельства или заводской номер |
---|---|---|---|---|
Не в реестре |
Normalised site attenuation (NSA) CISPR 16-1-4 | Site VSWR CISPR 16-1-4 | Field uniformity IEC/EN 61000-4-3 | |
Measurement distance | 3 m | 3 m | 3 m |
Frequency range | 200 MHz - 1 GHz | 1 GHz - 18 GHz | 80 MHz - 18 GHz |
Guaranteed performances | ± 4 dB | < 6 dB | 0 / +6 dB |
Compliance | Pre-compliant | Full-compliant | Full-compliant |
SHIELDING EFFECTIVENESS COMPLIES WITH EN 50147-1 (10 kHz - 40 GHz)
Radiated emission (EMI) testing: Fully compliant with the following standards from 30 MHz to 18 (40) GHz
|
|
Radiated immunity (EMS) testing: Fully compliant with EN/IEC 61000-4-3.
Radio standards: All ETSI standards referring to CISPR 16 and EN/IEC 61000-4-3.
› Dimensions (L x W x H)
Total overall with steel stiffeners | Internal usable dimensions |
8.3 x 4.6 x 3.4 m | 6.9 x 2.9 x 2.4 m |
27 x 15 x 11 ft | 23 x 9 x 8 ft |
› Quality
› About our absorbers
Подробные технические характеристики, информация производителя, брошюры:
-
Каталоги производителя: